Compact structural design greatly improves system energy density
Built in air duct design
establishing excellent heat transfer and conduction paths
Product design standardization
strong scalability
Adopting CANBUS2.0 communication protocol
BMS has real-time monitoring of voltage and temperature
as well as battery balancing functions
Adopting 1P52S string connection method
the PACK capacity is 46.592kWh.
Patented flow channel design
with a temperature difference of ≤ 2 ℃ at a flow rate of 5L/min.
FPC board welding
PACK level fire protection
achieving vehicle level safety and reliability.
Modular design
independent operation of each sub warehouse
reducing the scope of accident impact.
Multiple fire protection strategies: extremely early warning
PACK level fire protection
combustible gas monitoring+exhaust
heptafluoropropane or perfluorohexane
multiple sprays
end stage water fire protection
etc.
Intelligent industrial controller: 100 megawatt hour power plant second level data monitoring and recording.
Independent air cooling system: The cold and hot air ducts are designed independently
with precise thermal management technology.
Electrical load breaking: Refusing battery cluster fault reclosure.
The 20 foot liquid cooling scheme has a capacity of 3.727 MWh and an energy density increase of 8.3% compared to the conventional scheme.